Reset Search
 

 

Article

KB40944 - Pulse One is unable to distribute ip-address-pool element of connection profile from Master to the other group Appliance.

« Go Back

Information

 
Last Modified Date9/22/2017 6:17 PM
Synopsis
This article describes an issue where the Pulse One Appliance is unable to distribute the ip-address-pool element of connection profile from Master to the other group Appliance.
Problem or Goal
Pulse One administrator is unable to distribute the ip-address-pool element of connection profile from Master to the other group Appliance.

Behavior:
  • The PCS admin modify the IP pool on the Master appliance of the appliance group.
  • Than the admin tries to publish the changes to the other appliances in the appliance group.
  • Pulse One does not detect any change and Publish Required bottom does not get highlighted in this case.

 
Cause
Solution
This is a Working As Designed (WAD). This approach has been taken by the Pulse Secure to avoid IP conflict issues as it very unlikely for different sites to have same IP address range. In such cases recommendation is to use DHCP.
Related Links
Attachment 1 
Created ByKshitij Gupta

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255