KB45348 - IfHighSpeed Values Are Not Returning Correct Values in PSA 7000C

« Go Back

Information

 
Last Modified Date8/5/2022 3:58 AM
Synopsis
Problem or Goal
This issue is reported in 9.1 R12 and when we pull the results from snmp server for "ifhighspeed" the results are not returning the exact values as we see in admin gui neither switch interface results.
 
Cause
The speed for physical interfaces were not fetched properly from code, instead was being set as default.
Solution
This issue is resolved in 9.1 R14 and above versions