KB40269 - Unable to register appliance with error "error:14077102:SSL routines:SSL23_GET_SERVER_HELLO:unsupported protocol"

« Go Back

Information

 
Last Modified Date8/30/2016 2:43 PM
Synopsis
Problem or Goal
Failure to register appliance with Pulse One.
Cause
The appliance was required to negotiate a Zscaler proxy server to access the internet.
Solution

Pulse One connections are not supported via a proxy server. In one particular instance a customer was able to successfully connect via a Zscaler proxy server by disabling SSL inspection for the Pulse One URL.

 

To be clear Pulse Secure does not support proxy connections from an appliance to Pulse One.